Alliance Laundry Systems CI 1650/325 Troubleshooting, Temperature sensor out of order

Models: CI 1650/325

1 65
Download 65 pages 49.37 Kb
Page 42
Image 42
Troubleshooting

5

Troubleshooting

Starting problems

Fault

 

Cause

 

 

Remedy

 

 

 

No air has been exhausted.

 

 

Clean fan.

"No air" on display

 

 

 

Clean outlet tube.

 

 

 

Fan blocked.

 

 

Eliminate the fault.

 

 

 

Vacuum valve does not connect.

 

 

Check if the valve’s switch connects.

 

 

 

 

 

 

Check position/switching point of the switch.

 

 

 

Plug of vacuum valve is not inserted.

 

Insert the plug in the right input of the control.

 

 

 

Malfunction frequency converter.

 

 

See page 44.

"No speed" on

Frequency converter out of order.

 

 

See page 44.

display

 

Plug of drive is not inserted.

 

 

Insert the plug in the right input of the control.

 

 

 

Speed sensor does not detect pulses.

 

Adjust distance chain wheel and sensor to 1mm.

 

 

 

 

 

 

Out of order, replace sensor.

 

 

 

Burner in reset.

 

 

Open gas tap and reset burner.

 

 

 

Ionization follow-up cable not inserted well in

 

Insert plug well in burner and control print.

"No heat" on

contact of burner.

 

 

 

Plug of heating is plugged out of the burner.

 

Insert plug in right input of the control.

display

 

 

 

No gas in pipe at first set-up.

 

 

Make many start attempts, with resets in the

 

 

 

 

 

 

 

 

 

 

 

meantime, so that air is removed from the pipes.

 

 

 

Overheat switch tripped.

 

 

Check system and reset switch.

 

 

 

Fuse gas control broken.

 

 

Replace fuse after controlling system.

"Foot" on display

Foot pedal is operated.

 

 

Release the foot pedal.

 

 

 

Readjust the switch.

 

 

 

 

 

 

Tighten the springs.

"Heat1" or

Temperature sensor cable interrupted.

 

Check cable and repair defects.

"Heat2" on display

Temperature sensor out of order.

 

 

Replace the sensor by a new one.

(number of the

Input on control out of order.

 

 

Replace the control by a new one.

defective sensor)

 

 

 

 

Frequency converter

 

 

 

 

 

 

 

 

 

 

Fault

 

 

Condition

 

 

Possible cause

OI.AC**

 

Drive output instantaneous over current.

Insufficient ramp times.

 

 

 

 

Phase to phase or phase to ground short circuit on the drives

 

 

 

 

output.

 

 

 

 

 

Drive requires autotuning to the motor.

 

 

 

 

Motor or motor connections changed, re-autotune drive to motor.

It.AC

 

I²t on drive output current.

Excessive mechanical load.

 

 

 

 

High impedance phase to phase or phase to ground short circuit

 

 

 

 

at drive output.

 

 

 

 

 

Drive requires re-autotuning to motor.

HFxx trip

 

Hardware faults.

Internal drive hardware fault.