3

Air filters

Before operating the machine, the air filter(s) must be checked.

By removing the right door, you can check if the filter on the venturi of the gas valve is not blocked by something.

Important

Do not cover this filter at any time!

Exhaust gases

The exhaust gases of a gas-heated ironer must be inspected by an authorized mechanic. The gas burner needs to be adjusted at prevailing rules, gas sort and gas pressure.

The measured exhaust gases may not be higher than the current rules.

Check the exhaust pipe on leaks and repair this, if so.

23

Page 23
Image 23
Alliance Laundry Systems CI 2050/325, CI 1650/325 instruction manual Air filters, Exhaust gases