Installation
Machine Foundation
For machine foundation information for both UWPV and UFPV models, refer to section in respective installation/maintenance manuals.
For UFPV models with the Water Saving System, refer to Table 1 for total floor load data.
UFPV Cabinet Freestanding
Floor Load Data
| 35 | 50 | 85 |
|
|
|
|
Static floor load, | 2193 | 2675 | 5052 |
lbs (kN) | (9.755) | (11.899) | (22.472) |
|
|
|
|
Static Pressure, | 231 | 239 | 313 |
lbs/ft2 (kN/m2) | (11.07) | (11.45) | (15.00) |
Table 1
Water Saving Tank Frame Foundation for Pocket Hardmount Models (UWPV)
A proper frame foundation is absolutely necessary for all UWPV
NOTE: Do not mount on wooden floors, above ground level, or over basements. Installation must be “slab on grade” or equal.
IMPORTANT: Ensure that the tank frame is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
The tank frame must be anchored to a smooth level surface so that all four legs are supported and rest on the mounting surface.
If the
Static
UWPV Pocket Hardmount
Floor Load Data
| 60 | 100 |
|
|
|
Static floor load, | 2617 | 4341 |
lbs (kN) | (11.7) | (19.3) |
|
|
|
Static pressure per leg, | 227 | 271 |
lbs/ft2 (kN/m2) | (10.9) | (13.0) |
Table 2