e. Remove the four bolts from each tank located behind cap plug at each corner. Refer to Figure 9.

f. Lift tanks off the washer-extractor.

CAUTION

Be extremely careful when removing tanks. To prevent damage, always place tanks on a level surface with clean-out access facing up.

2.Removing the pump assembly:

a.Remove manifold hose clamps connecting the pump manifold to the drain valve found at the

rear of the washer-extractor to the right of the pump assembly. Refer to Figure 9.

b.Unscrew the two pump motor electrical quick disconnects from the water saving control housing located at the rear of the washer- extractor.

c.Slide off the long black hoses that run from the water tanks. Refer to Figure 9.

d.Remove pump assembly and place to the side.

3.Positioning and bolting down the washer- extractor:

Refer to Mechanical Installation Section for boltdown instructions.

2

5

3

 

4

 

Q008I

 

 

 

 

 

 

Q008I

1

Corner Tank Bolts (4 per Tank)

4

Pump Assembly

2

Hose Clamps on Elbows

5

Cap Plug

3Manifold Hose Clamps

Figure 9

20

F232122