Installation
e. Remove the four bolts from each tank located behind cap plug at each corner. Refer to Figure 9.
f. Lift tanks off the
CAUTION
Be extremely careful when removing tanks. To prevent damage, always place tanks on a level surface with
2.Removing the pump assembly:
a.Remove manifold hose clamps connecting the pump manifold to the drain valve found at the
rear of the
b.Unscrew the two pump motor electrical quick disconnects from the water saving control housing located at the rear of the washer- extractor.
c.Slide off the long black hoses that run from the water tanks. Refer to Figure 9.
d.Remove pump assembly and place to the side.
3.Positioning and bolting down the washer- extractor:
Refer to Mechanical Installation Section for boltdown instructions.
2
5
3
| 4 |
| Q008I |
|
|
| |
|
|
| Q008I |
1 | Corner Tank Bolts (4 per Tank) | 4 | Pump Assembly |
2 | Hose Clamps on Elbows | 5 | Cap Plug |
3Manifold Hose Clamps
Figure 9