Programming

NOTE: The following programming information is for both Cabinet Freestanding and Pocket Hardmount models with the Water Saving System (WSS). Use in conjunction with respective operating/programming manuals.

When programming steps using the WSS, the computer must be in the PROGRAM mode and ready for the next step. The display will read “nncc”, where “nn” represents step number and “cc” represents cycle number.

Programming a Recovery Fill from Water Saving Tank(s)

1.Press the Auxiliary key. The display will read “A-nncc”.

2.Press key 6 to select a fill from tank A. The display will read “a-nncc”. To select a fill from tank B, press key 7 instead. The display will read “b-nncc”.

3.Press the Low, Medium, or High key to select a water level. The second digit of the display will read either “L”, “M,” or “H”, respectively for a low, medium, or high water level. For example, if a low level fill from tank A is selected, the display will read “aLnncc”.

4.Press the Enter key. The display will now read “M---S”.

5.Enter the desired maximum fill time. To program 5 minutes, press key 5. The display will read “5M-00S”.

6.Once the desired time had been entered, press the Enter key to go to the next step of the cycle or to exit PROGRAM mode.

Programming a Water Saving Drain Step

1.Press the Drain key. The display will read “D-nncc”.

2.Press key 2 to drain tank A or key 3 to drain to tank B. The display will read “Danncc” if tank A is selected and “Dbnncc” if tank B is selected.

3.Press the Enter key. The display will read “M---S.”

4.Enter the desired time for the drain step. For example, to enter a time of five minutes, press key 5. The display will show “5M-00S.”

NOTE: If machine does not empty in this amount of time, “EMTY”, will be displayed.

5.Press the Enter key and go to the next step in the cycle or the PROGRAM mode may be exited.

NOTE: When programming a drain step, it is necessary to specify which type of drain is desired, because water saving features are available at all times.

NOTE: The WE-6 computer will not permit draining into a tank if the water temperature exceeds 160 degrees Fahrenheit. In that event, the display will show “DRTEMP”, the WE-6 will turn off all outputs (except applicable drain[s]) and will sound the buzzer. This will continue for up to two minutes. If the operator does not respond within two minutes the WE-6 aborts the cycle. The operator can press the START key to begin the drain step again, or press the STOP key to end the cycle.

Programming Cycles

Refer to the Programming section in the Operation/ Programming manuals (P/N F232059 for UF models, P/N F232089 for UW models) for preprogrammed cycles.

F232122

29