Instructions for Installation of Cabinet Freestanding Models (UFPV) with Water Saving System
Read the following instructions thoroughly before proceeding. The installer must have a comprehensive understanding of the instructions before attempting installation of the WSS.
Refer to the WSS Electrical Specifications for voltage information.
Refer to the WSS General Specifications to determine if there is adequate clearance through the door for the machine. If not, removal of the water tanks is necessary.
Installation
1.Removing the water tanks (if necessary):
a.Remove the three cap plugs located near the rear and one located near the front on each side of the tanks. Refer to Figure 8.
b.Loosen the two hose clamps attached at the bottom rear of each tank. Refer to Figure 8.
c.Loosen the hoses clamps attached to the elbow at the rear of each tank and slide off the long black hoses that run from the tanks. Refer to Figure 9.
d.Loosen the hose clamp to the short black hose between each tank and remove from only one tank.
1
2
3
4
5
Q007I
1Water Tanks
2Vacuum Vents
3Water Saving Control Housing
4Cap Plug
5Hose Clamps Under Tank, Behind Plug
Figure 8
F232122 | 19 |