Operating Instructions

ON / SELECT

 

STATUS

PROGRAM

 

HIGH

START

DRYING

AUTO

TIME

 

 

 

 

 

 

AUTO

 

MEDIUM

STOP/RESET

COOL DOWN

SPECIAL

SPECIAL

CYCLE

TIME

MED LOW

TEMP

DOOR OPEN

*TEMPAUTO

COOL

 

DISPLAY

 

 

*DOWN

 

F/ C

 

 

 

LOW

SIGNAL

CUSTOM

MORE

LESS

 

 

 

+

--

NO HEAT

REVERSING

 

CONDITION

SAVE

 

 

 

CUSTOM

 

 

 

 

PROG

T359I

T359I

Figure 6

Electronic OPL Control

1.To use an Automatic Cycle, press an ON/ SELECT pad. Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT for items that should not be dried with heat. A light to the left of the selected pad lights up.

To use a Time Dry or Custom Cycle, refer to section Programming the Electronic OPL Control.

NOTE: Do not press directly on lights or the center of pad. For proper selection, press on pad slightly to the right of center. Refer to Figure 7.

2. Press START pad to start tumbler.

NOTE: All pads can be pressed in any sequence without damaging control or tumbler. To stop the tumbler at any time, open the door or press STOP/ RESET. The window display will flash. Press STOP/RESET twice (within 3 seconds) to end the cycle and reset the control to idle status. To restart the tumbler, CLOSE door and press START pad.

WARNING

To reduce the risk of bodily injury, the tumbler stops tumbling when the door is opened. Do not use the tumbler if it does not stop tumbling when the door is opened or starts tumbling without pressing the START pad. Remove the tumbler from use and call for service.

W078

3.When the cycle is complete, open door and remove the laundry.

T306I

Figure 7

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414462