Temperature Sensor

To test the temperature sensor, hold COOL DOWN pad and press the TEMP pad in the idle mode. This will show the temperature detected by the control.

SH” displays and signal sounds if the temperature sensor is shorted or sensor temperature is over 200°F (93°C). Press the STOP/RESET pad twice within 3 seconds and allow the tumbler to cool, then press an ON/SELECT pad. If “SH” still displays, call for service.

OP” displays and signal sounds 3 minutes after the tumbler is started if the temperature sensor is faulty or if a temperature below 24°F (-4.4°C) is detected. If dryer temperature is above 24°F (-4.4°C), call for service.

NOTE: To display the software revision level, hold the AUTO pad and press the TIME pad while the control is in idle mode.

Temperature Adjustment

Selecting a fabric type selects a preset ideal temperature for that fabric. Lower temperatures may be needed for small loads or when air flow through the tumbler is less than ideal due to inadequate make-up air or exhaust ducting.

Whenever the control is on, but not in NO HEAT, COOL DOWN or LOAD READY, pressing the TEMP pad displays the three digits of the set temperature. Use the MORE or LESS pad to increase or decrease the temperature.

Temperature Display (°F/°C)

To select between Fahrenheit and Celsius display, hold in the TEMP display pad while pressing the TEMP pad.

NOTE: Temperature can be set from 80°F (27°C) to 180°F (82°C) in the SPECIAL CYCLE and SPECIAL TIME options only.

To include an adjusted temperature in a Custom cycle, simply adjust temperature before pressing CUSTOM.

Cylinder Temperature Display

To see the approximate temperature at the exit of the cylinder, press and hold the TEMP DISPLAY pad (50-170# Models Only).

Programming the Electronic OPL Control

 

Control

Desired

 

Program

Clothes

Temperature

Temperature

Temperature

 

 

 

 

°F (°C)

°F (°C)

Selection

 

 

 

 

 

 

0220S

 

0220S

 

 

0270S

0350S

0270S

0350S

 

 

 

 

 

 

140 (60)

145 (63)

185 (85)

190 (88)

 

 

 

 

 

 

135 (57)

140 (60)

180 (82)

 

 

 

 

 

HIGH

130 (54)

135 (57)

170 (77)

175 (79)

 

 

 

 

 

 

125 (52)

130 (54)

160 (71)

165 (74)

 

 

 

 

 

 

120 (49)

125 (52)

155 (68)

160 (71)

 

 

 

 

 

 

125 (52)

130 (54)

160 (71)

165 (74)

 

 

 

 

 

 

120 (49)

125 (52)

155 (68)

160 (71)

 

 

 

 

 

MEDIUM

115 (46)

120 (49)

150 (66)

155 (68)

 

 

 

 

 

 

110 (43)

115 (46)

145 (63)

 

 

 

 

 

 

105 (41)

110 (43)

135 (57)

140 (60)

 

 

 

 

 

 

110 (43)

120 (49)

145 (63)

155 (68)

 

 

 

 

 

 

105 (41)

115 (46)

135 (57)

145 (63)

 

 

 

 

 

MED LOW

100 (38)

110 (43)

130 (54)

140 (60)

 

 

 

 

 

 

95 (35)

105 (41)

120 (49)

135 (57)

 

 

 

 

 

 

90 (32)

100 (38)

105 (41)

125 (52)

 

 

 

 

 

 

95 (35)

120 (49)

 

 

 

 

90 (32)

105 (41)

 

 

 

LOW

85 (29)

100 (38)

 

 

 

 

80 (27)

95 (35)

 

 

 

 

75 (24)

95 (35)

 

 

 

 

 

Table 4

M414462

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25