Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumbler before servicing.

Close gas shut-off valve to gas tumbler before servicing.

Close steam valve to steam tumbler before servicing.

Never start the tumbler with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

Every Three Months

Lint Removal

1.Clean the lint and any other foreign materials from the air vents located on the motors. The motors are air cooled and if the air vents become clogged, the motor will overheat and the internal thermal overload protector will cycle off.

2.Steam Models: Check the steam coils and remove any lint buildup and/or replace air filter in the coil fin area. This can be accomplished by using compressed air or by fabricating a comb that can be pulled across the fins of the coil.

3.Exhaust ducts should be periodically inspected to ensure there has been no build-up of lint which could obstruct the air flow.

4.Inspect the dryer area to make sure nothing is obstructing the flow of combustion and ventilation air.

5.Remove front panel and clean any lint buildup.

Belt Tension

Check belt tension and adjust if needed.

Every Six Months

Overall Check

Check the tumbler over thoroughly for loose nuts, bolts and screws, and for loose gas, electrical and/or steam connections.

GAS CONNECTIONS: (Unions, flared tube fittings) Check for leakage that might be caused by vibration. Use a non-corrosive leak detention fluid. DO NOT

USE A FLAME AT ANY TIME TO CHECK FOR GAS LEAKS.

ELECTRICAL CONNECTIONS: Electrical service and grounding connections should be examined for proper tightness.

M414462

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT