Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumbler before servicing.

Close gas shut-off valve to gas tumbler before servicing.

Close steam valve to steam tumbler before servicing.

Never start the tumbler with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

1

WARNING

2

T046I

50 – 170 POUND TUMBLERS

T046I

1Thermostat Sensing Probe

2Lint Screen

Figure 17

Monthly

Lubrication

Motor bearings, roller bearings and trunnion bearings are sealed bearings and require no lubrication.

Lint Removal

Remove the exhaust duct from the exhaust thimble and remove lint. If excessive lint is evident at the thimble, further disassemble the duct work and remove lint.

Energy Saver Gas Models: Remove the cleanout cover at the bottom of the vertical duct and clean out lint.

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414462