Allied Telesis AT-9408LC/SP manual Cable Type Auto-MDI/ MDI-X Port Pinouts, Maximum Distance

Models: AT-9408LC/SP AT-9424T/POE

1 84
Download 84 pages 26.03 Kb
Page 27
Image 27

Maximum Distance

Cable Type

Auto-MDI/ MDI-X

Port Pinouts

AT-9400 Series Gigabit Ethernet Switches Installation Guide

The ports have a maximum operating distance of 100 meters (328 feet).

The cabling requirements for a 10/100/1000Base-T port are:

ˆFor 10 Mbps operation: Standard TIA/EIA 568-B-compliant Category 3 or better shielded or unshielded cabling with 100 ohm impedance and a frequency of 16 MHz.

ˆFor 100 Mbps operation: Standard TIA/EIA 568-A-compliant Category 5 or TIA/EIA 568-B-compliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz.

ˆFor 1000 Mbps operation: Standard TIA/EIA 568-A-compliant Category 5 or TIA/EIA 568-B-compliant Enhanced Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm impedance and a frequency of 100 MHz.

The twisted pair ports on the switch are IEEE 802ab-compliant and feature auto-MDI/MDI-X. This feature, available when a port’s speed and duplex mode are set through Auto-Negotiation, automatically configures a switch port to MDI or MDI-X depending on the wiring configuration of the port on the end node. This allows you to connect any network device to a port on the switch using a straight-through twisted pair cable.

If Auto-Negotiation is disabled on a port and the speed and duplex mode are set manually, the auto-MDI/MDI-X feature is also disabled and the port’s wiring configuration defaults to the MDI-X setting. This setting can be configured with the AT-S63 Management Software.

Refer to Table 13 on page 80 for the port pinouts when a twisted pair port operates at 10 or 100 Mbps in the MDI configuration and Table 14 on page 80 for the MDI-X configuration. For port pinouts when a twisted pair port operates at 1000 Mbps, refer to Table 15 on page 81.

27

Page 27
Image 27
Allied Telesis AT-9408LC/SP, AT-9424T/POE manual Cable Type Auto-MDI/ MDI-X Port Pinouts, Maximum Distance