26 Installation
Note
A point to notice
Info.
Supplementary information
Connections for Various Functions

Alarm Recording Connection

The alarm can be confirmed from a distance by connecting the
ALM OUT terminal with an existing alarm system panel or other
peripherals such as a buzzer. Connect the VCR and other
peripherals as to the right. ( page 11 for the menu setting
and page 36 for the rating of each terminal)
Alarm set switch
Alarm reset switch External alarm lamp
and buzzer
RST
IN REC GND ALMALM
MODE
CLK
OUT CALL
AUDIO VIDEO
OUT OUTIN
REMOTE
IN
RESET
RST
IN REC GND ALMALM
MODE
CLK
OUT CALL
MIC
VIDEO
OUT
AUDIO
OUT
MIC
IN
VIDEO IN
AUDIO IN
SENSOR CCTV CAMERA
ALM IN GND
VIDEO
IN
VIDEO OUT
MONITOR
MICROPHONE

Connecting with CCTV camera, monitor and sensor

Note
Monitor to be connected
Connecting with a CCTV monitor (for surveillance) is recommended.
Connecting with some monitors may cause picture vibration and/or picture distortion at the top or bottom of the image at still
picture or normal playback.
A television for domestic use may easily cause the picture vibration and distortion.
CCTV camera to be connected
Do not connect ‘Color’ and ‘Black & White’ cameras together.