Control Input/Output Signals and Circuit

ALM/RST/REC IN terminals (screw)

Active

: When input terminals are short-circuited to

 

GND or “L” level voltage (0 to +1.6 V) applied.

Time for active

: 0.1 sec. or over.

Non active

: Open the input.

22 kΩ

ALM/RST/REC IN

DC 5 V

10 kΩ

0.047 F

GND

22 kΩ

ALM/MODE/CALL OUT terminals (screw)

Active

: “L” level voltage (0 to + 0.4 V) output;

 

max. drive current 50 mA (+5 V DC)/10 mA

 

(+24 V DC)

Non active

: Open; max. voltage +24 V DC

CLK OUT terminals (screw)

<Interface circuit inside the VCR>

ALM/MODE/CALL OUT

GND

<Interface circuit inside the VCR>

DC 12 V

10 kΩ

CLK OUT

100Ω

GND

CLK OUT signal

When F is selected in CLOCK OUT of REAR TERMINAL menu (at 6H or 8H mode) or while recording in L18H-128H or 0H mode.

When REC-1 to REC-60 is selected in CLOCK OUT of REAR TERMINAL menu (at 6H or 8H mode).

<Interface circuit inside the VCR>

+12 V

0 V

8 ms

+12 V

0 V

16 ms

36 Others

Note A point to notice

Info. Supplementary information

Page 40
Image 40
American Dynamics ADV096HD Control Input/Output Signals and Circuit, ALM/RST/REC in terminals screw, CLK OUT signal