NO.

Commands

 

Functions

 

Status after normal exection

Explanation of status

34

MC

 

#1

 

Switch over REC/PLAY mode to

RC #2 EX #2

 

 

Command received and carried out

 

 

 

 

 

= 006, L18, L30, 048, 072, 096, 000

 

 

 

 

 

 

35

MD #1

 

 

Enquiry about current REC/PLAY mode

RC #2 MD

(1)

#2

 

 

(1): (same as item 34)

 

 

 

 

 

 

 

 

 

 

36

DP #1

 

 

 

Change menu to the next layer

RC #2 EX #2

 

 

Command received and carried out

37

DP

 

#1

 

Switch screen page to

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

 

 

000=present time display

 

 

 

 

 

 

 

 

 

 

 

100=MAIN MENU

 

 

 

 

 

 

 

 

 

 

 

110=DISPLAY menu

 

 

 

 

 

 

 

 

 

 

 

120=SEARCH FUNCTION menu

 

 

 

 

 

 

 

 

 

 

 

121=TIME DATE SEARCH menu

 

 

 

 

 

 

 

 

 

 

 

130=TIMER PROGRAM menu

 

 

 

 

 

 

 

 

 

 

 

131=PROGRAM TO RECORD menu

 

 

 

 

 

 

 

 

 

 

 

132=HOLIDAY SET UP menu

 

 

 

 

 

 

 

 

 

 

 

140=RECORDING SET UP menu

 

 

 

 

 

 

 

 

 

 

 

150=REAR TERMINAL menu

 

 

 

 

 

 

 

 

 

 

 

160=MAINTENANCE menu

 

 

 

 

 

 

 

 

 

 

 

161=POWER LOSS LIST

 

 

 

 

 

 

 

 

 

 

 

162=ALARM LIST

 

 

 

 

 

 

 

 

 

 

 

163=ALL MENU INITIALZE

 

 

 

 

 

 

 

 

 

 

 

164=POWER LOSS LIST CLEAR

 

 

 

 

 

 

 

 

 

 

 

165=ALARM LIST CLEAR

 

 

 

 

 

 

 

 

 

 

 

170=FIRST TIME SET UP menu

 

 

 

 

 

 

 

 

 

 

 

171=TIME DATE ADJUST menu

 

 

 

 

 

 

 

 

 

 

 

172=RS-232C menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

PI #1

 

 

 

Enquiry about current screen page

RC #2 ON

(1)

(2)

#2

 

(1):(same as item 37),

 

 

 

 

 

 

 

 

 

 

 

050=LANGUAGE SELECT

 

 

 

 

 

 

 

 

 

 

 

(2)

: 0=Setting completed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=Setting underway

39

SD

(1),

(2),

(3) #1

Current date setting

RC #2 EX #2

 

 

Command received and carried out

 

 

 

 

 

(1):Month,

(2):Day, (3) :Year

 

 

 

 

 

 

40

DT #1

 

 

 

Enquiry about current date

RC #2 TD

(1),

(2),

(3), (4) #2

(1),- (3):(same as item 39)

 

 

 

 

 

 

 

 

 

 

 

(4):Day of the week

 

 

 

 

 

 

 

 

 

 

 

0=SUN, 1=MON, 2=TUE,

 

 

 

 

 

 

 

 

 

 

 

3=WED, 4=THU, 5=FRI, 6=SAT

41

SC

(1),

(2)

#1

Current time setting

RC #2 EX #2

 

 

Command received and carried out

 

 

 

 

 

(1):Hour,

(2):Minute

 

 

 

 

 

 

42

TM #1

 

 

 

Enquiry about current time

RC #2 TI

(1),

(2),

(3) #2

(1):Hour, (2):Minute, (3):Second

43

TD #1

 

 

 

Enquiry about power failure symbol

RC #2 MK

#2

 

 

: 0=Not Displayed, 1=Displayed

44

PS

(1),

(2)

#1

Time and date display position

RC #2 EX #2

 

 

Command received and carried out

(1):Horizontal

=01-30 (mode 1,size large) =01-52 (mode 1,size small) =01-39 (mode 2,3 size large) =01-62 (mode 2,3 size small) (2):Vertical

=01-37 (mode 1,size large or small) =01-35 (mode 2,3 size large or small)

45

LC #1

 

 

 

 

Enquiry about time and date display

RC #2 LT

(1),

(2)

#2

 

(1),

(2) : (same as item 44)

 

 

 

 

 

 

position

 

 

 

 

 

 

 

46

PG (1),

(2),

(3),

(4),

Timer program setting

RC #2 EX #2

 

 

 

Command received and carried out

 

(5),

 

(6),

(7),

(8) #1

(1)Program No.=1-8

 

 

 

 

 

(Note) An error (ER08) will occur if an

 

 

 

 

 

 

(2):Day of the week (0=SUN, 1=MON,

 

 

 

 

 

attempt is made to program a timer program

 

 

 

 

 

 

2=TUE, 3=WED, 4=THU, 5=FRI, 6=SAT,

 

 

 

 

 

number that has already been set. Clear the

 

 

 

 

 

 

7=DAY, 8=SPL,9=HLD)

 

 

 

 

 

timer program contents with the "CA "

 

 

 

 

 

 

(3):Rec. starting hour=00-23

 

 

 

 

 

command and then retry.

 

 

 

 

 

 

(4):Rec. starting minute=00-59

 

 

 

 

 

 

 

 

 

 

 

 

 

(5):Rec. ending hour=00-23

 

 

 

 

 

 

 

 

 

 

 

 

 

(6):Rec. ending minute=00-59

 

 

 

 

 

 

 

 

 

 

 

 

 

(7):Rec. time mode= (same as item 34),

 

 

 

 

 

 

 

 

 

 

 

 

 

SKP

 

 

 

 

 

 

 

 

 

 

 

 

 

(8):REC mode 1=EP, 3=EP/EXT

 

 

 

 

 

 

 

 

 

 

 

 

 

(EXT= external timer recording)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

PM

#1

 

 

 

Enquiry about setting contents of timer

RC #2 MP

(1),

(2),

(3), (4), (5),

(6),

(1),-

(8) (=same as item 46)

 

 

 

 

 

 

program No. ( =1-8)

(7) (8) #2

 

 

 

 

 

48

CA

#1

 

 

 

Clear contents of timer program No. ( =1-8)

RC #2 EX #2

 

 

 

Command received and carried out

49

DW

(1),

(2)

#1

 

Setting the special day of the week

 

 

 

 

 

 

 

 

 

 

 

 

 

(1):Start day of the week (0-6)

(Cannot accept this command when

(1)and

 

 

 

 

 

 

 

 

(2):End day of the week (0-6)

(2)are the same number)

 

 

 

 

 

 

 

 

 

0=SUN, 1=MON, 2=TUE, 3=WED,

 

 

 

 

 

 

 

 

 

 

 

 

 

4=THU, 5=FRI, 6=SAT

 

 

 

 

 

 

 

Reference page

Advanced Functions 23

Page 27
Image 27
American Dynamics ADV096HD operation manual 100=MAIN Menu