RS-232 Control Commands / Messages
63
Delta Series Audio Controllers

RS-232 Control Commands / Messages

Delta Audio Controllers provide an RS-232 (DB9) port for receiving RS-232 Controller Commands.
Refer to the RS-232 Controller Command Messages section on page 55 for a complete listing of
supported commands.
Connector: DB9 Male
Communications: 4800 Baud, 8 data bits, 1 stop bit, no parity
The Matrix Distributed Audio, multi-room audio control systems can be externally controlled by sending
ASCII text command strings to the Bi-Directional RS-232 serial interface. Every command must be
terminated with a line feed (0x0A). All messages are case-sensitive.
The MRC will respond to command messages with a status response message once the command has
been executed.
This section provides reference information for the following:
RS-232 Controller Command Messages - These commands can be sent directly to the Delta
Audio Controller via the RS-232 (DB9) port on the rear panel. See the Connecting the RS-232
Serial Port section on page 19 for connection and DB9 cabling information.
Delta Audio Controller Status Messages (page 67) - These messages are received via the
RS-232 port, and are used primarily for troubleshooting purposes.
Source Command Codes (page 70) - Source Command Codes, received from the SWT
keypads are referenced here by Source Type and Command Index.

RS-232 Controller Command Messages

RS-232 Controller Command Messages
MVER Get Firmware Version Firmware Status Version
- or -
ERR
MGCF Get Configuration Configuration Status
- or -
ERR
FNIC Get Number of IIC devices Num IIC Devices Status
- or -
ERR
FGICx Get IIC Device Status, where:
x’ is the IIC device index, valid values range from 1 to the
number of available IIC devices as reported in the ‘Num IIC
Devices Status’
IIC Device Status
- or -
ERR
MSVLr,v Set Volume, where:
•‘r’ is the desired room, (1-64)
•‘v’ is the desired volume level, valid values are:
101: Mute
0....70: 0....-70 dB
Volume Status
- or -
ERR
MGVLr Get Volume, where:
r’ is the desired room, (1-64)
Volume Status
- or -