RS-232 Control Commands / Messages
69
Delta Series Audio Controllers

Controller Status Messages (Cont.)

MPRSs,n,p Preset Status, where:
•‘s’ is the source, valid values are 1-8
•‘n’ is the preset, valid values are 1-10
•‘p’ is the direct tuning string; it can be from 0 to 7 characters long and is translated
as specified in the ‘Send Source Direct Data’ command: Zero length data is
returned if no preset is set
MSTPs,t Source Type Status, where:
•‘s’ is the source, valid values are 1-8
•‘t’ is the source type, valid values are:
0: undefined
1: AM/FM Tuner
2: CD Changer
3: DVD Player
4: Satellite Receiver
5: Audio Server
6: Other 1
20: Internal AM/FM Tuner
MSSTs,p,x Source Status, where:
•‘s’ is the source, valid values are 1-8
•‘p’ is the source state, valid values are:
0: Off
1: On
2: Paused
3: Mute off (Sirius module only)
4: Mute on (Sirius module only)
5: Sleep on (Sirius module only)
•‘x’ is a variable length data string that varies with the type of source:
0: undefined p where:
1: AM/FM Tuner – b,m,f where:
b’ is the band: 1 = AM, 2 = FM
m’ is the mono/stereo status: 1 = mono, 0 = stereo
f’ is the currently tuned frequency (if it is known) (5 digits max)
2: CD Changer - none
3: DVD Player - none
4: Satellite Receiver - none
5: Audio Server - none
6: Other 1 – none
7: Custom XM – none
8: Internal Sirius Tuner - none
20: Internal AM/FM Tuner b,m,s,fffff where:
b’ is the band: 1 = AM, 2 = FM
m’ is the mono/stereo status: 1 = mono, 0 = stereo
s’ is the seek/tune status: ‘1’ = seek, ‘0’ = tune
f’ is the currently tuned frequency (5 digits max)
CSTh,m,s,M,D,Y,x Clock Status, where:
•‘h’ is the desired hour, (0-23)
•‘m’ is the desired minute, (0-59)
•‘s’ is the desired second, (0-59)
'M' is the Month, (01-12)
'D' is the Date, (01-31)
'Y' is the Year, (2000-2099)
'x' is the day of the week, (MON-SUN)