Image 9
NI-3100 Specifications

Introduction

NI-3100 Specifications

The NI-3100 (FIG. 3) provides support for 7 RS-232/RS-422/RS-485 Ports, 8 IR/Serial Output ports, 8 Digital Input/Output ports, and 8 Relays.

The NI-3100 can be upgraded to provide one ICSHub and two ICSNet ports by either installing the optional ICSNet daughter card (FG2105-10) or purchasing this upgrade as an included feature of the NI- 3100 Kit (FG2105-15).

FIG. 3 NI-3100 NetLinx Integrated Controller (front view)

Link/Active-Status-Output-Input

RS-232/422/485 TX/RX LEDs (red/yellow)

Relay LEDs (red)

IR/Serial LEDs (red)

LINK/ACT

INPUT

1

2

3

4

5

6

7

STATUS

OUTPUT

TX RX TX

RX TX

RX TX

RX TX

RX TX RX

TX RX

 

 

RS - 232 / 422 / 485

 

 

1 2 3 4 5 6 7 8

RELAYS

1 2 3 4 5 6 7 8

IR / SERIAL

1 2 3 4 5 6 7 8

I / O

I/O LEDs (yellow)

Front

AXlink LED

(green)

ICSNet cover plate

Rear

RS-232/422/485 (Ports 1-7)

IR/Serial (Ports 9-16)

RS - 232 / 422 / 485

 

(Ports 1-7)

 

Pin Function

Pin

Function

1

RX-

6

RX+

2

RXD

7

RTS

3

TXD

8

CTS

4

TX+

9

TX-

5

GND

 

 

Relays

 

I/O (Port 17)

Program

 

 

 

DIP

(Port 8)

 

 

port

 

 

 

 

 

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

ID Pushbutton

FIG. 4 NI-3100 front and rear panel connectors and components

AXlink port

Ethernet

PWR