AMX NI-3100, NI-4100 Introduction, NI-2100 Specifications, Flash size provided, Front Panel LEDs

Models: NI-2100 NI-3100 NI-4100

1 36
Download 36 pages 4.69 Kb
Page 7
Image 7
NI-2100 Specifications

Introduction

NI-2100 Specifications

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)

 

• 2 rack units high

 

 

Power Requirement:

700 mA @ 12 VDC

 

 

Memory:

• 64 MB SDRAM

 

• 1 MB Non-volatile (NV) SRAM

 

 

Compact Flash:

128 MB or more - Upgradeable (see Other AMX Equipment)

 

Note: AMX may increase Flash size at any time in response to

 

market availability (refer to product’s online catalog page for current Compact

 

Flash size provided).

 

 

Weight:

4.50 lbs (2.04 kg)

 

 

Enclosure:

Metal with black matte finish

 

 

Certifications:

FCC Part 15 Class B, CE, and IEC 60950

 

 

Front Panel LEDs:

 

 

 

• LINK/ACT:

Green LED blinks when the Ethernet cables are connected and

 

terminated correctly. Also blinks when receiving Ethernet data

 

packets.

 

 

• Status:

Green LED blinks to indicate that the system is programmed and communi-

 

cating properly.

 

 

• Output:

Red LED blinks when the Controller transmits data, sets channels On and

 

Off, sends data strings, etc.

 

 

• Input:

Yellow LED blinks when the Controller receives data from button pushes,

 

strings, commands, channel levels, etc.

RS-232/422/485:3 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 3 are trans-

mitting or receiving RS-232, 422, or 485 data.

• Relay:

4 red LEDs light to indicate the relay channels 1 - 4 are active (closed).

 

These LEDs reflect the state of the relay on Port 4.

 

 

• IR/Serial:

4 red LEDs light to indicate the IR/Serial channels 1 - 4 are

 

transmitting control data on Ports 5 - 8. LED indictor for each IR port remains

 

lit for the length of time that IR/Serial data is being generated.

 

 

• I/O:

4 yellow LEDs light when the I/O channels 1 - 4 are active. The LED for each

 

I/O port reflects the state of that particular port.

 

 

Rear Panel Components:

 

RS-232/422/485 (Ports 1 - 3): 3 RS-232/422/485 control ports using DB9 (male) connectors with XON/ XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud.

• ICSNet:

2 RJ-45 connectors for ICSNet interface (provided by optional

 

ICSNet daughter card).

 

 

• ICSHub Out:

RJ-45 connector provides data to a Hub connected to the Controller (pro-

 

vided by optional ICSNet daughter card).

 

 

• Relay (Port 4):

Four-channel single-pole single-throw relay ports

 

• Each relay is independently controlled.

 

• Supports up to 4 independent external relay devices

 

• Channel range = 1-4

 

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

 

8-pin 3.5 mm mini-Phoenix (female) connector provides relay termination

Digital I/O (Port 9):4-channel binary I/O port for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports.