Appendix B – Programmer’s Interface for System Diagnostics
Verbosity Settings
The verbosity (v) settings (v0, v1, v2, v3) correspond to the level of detail that will be displayed, with v0 being the lowest level of detail and v3 being the highest level. The v3 setting is not supported for the “all components” setting. The commands ~scr! or ~scri0v#! will access the lowest level of detail (verbosity) for all components. The command ~scri#v#! will display higher levels of detail depending on the values entered for the verbosity settings.
Note: The “all components” setting (0) will display the lowest level of detail no matter which verbosity setting is used.
Component Settings
Detailed information for a single system component can be specified by using its identity (i) number setting (i0 through i4 and i7) in the following table. The “all components” setting (i0) will display the lowest level of detail no matter which verbosity setting is used.
Component | Identity Number Setting |
|
|
All Components | i0 |
Enclosure | i1 |
Storage Blocks | i2 |
Communication Interfaces | i3 |
Hardware & Boards | i4 |
System Sensors | i7 |
Tip: The information in the above table is displayed when you enter ~scr! or ~scri0v1!
General Rules for Octaire Diagnostic Commands
In a
If the verbosity setting is omitted, the verbosity level will be the lowest (v0)
The component setting must be included; otherwise, entering any of the verbosity settings alone will result in a display equivalent to i0v0
If both settings are omitted during a query (~scr!), the information displayed will be at the lowest verbosity level for all components (i0v0)
At system boot, the information for an scri1v0! command is displayed
To access the lowest level of verbosity for all components:
1.Enter ~scr! or ~scri0v#! (# = any verbosity setting)
To access a specific level of verbosity for a specific component:
2.Enter ~scri#v# where the first # is the component (identity) setting and the second # is the verbosity setting (either may be specified first).
All combinations are valid except for v3i0, which is not supported.
3.Enter ! (to send the command).
Example: ~scrv3i7! or ~scri7v3! (displays the highest level of detail for the system sensors).
98 | Octaire Instruction Manual |