AMX Octaire instruction manual Opening the APWeb Server, System Requirements, Design Requirement

Models: Octaire

1 106
Download 106 pages 7.86 Kb
Page 73
Image 73
System Requirements

APWeb – Initial Setup by Network Admin

System Requirements

PC with Windows XP Professional®, Windows 2000®, or Windows NT®

Web browser (Internet Explorer, Firefox, Netscape, etc.)

JRE v1.4.x or greater (Java Plug-in for the XBar Controller, see page 72)

Design Requirement

AMX highly recommends deploying only one APWeb server per system. Any configuration violating this recommendation may not be backed by the technical support agreement. APWeb offers a single, remote access point to a system, and its interactions with that system can cause interference and collision issues if more than one APWeb server is present.

Opening the APWeb Server

Caution: We strongly recommend that the APWeb server site be placed inside your network firewall and that system security be turned on.

A worksheet to record connection information is provided at the end of this chapter (see page 86).

To set up the APWeb server:

1.Follow the directions on page 35 for connecting the TCP/IP connector on the Octaire’s CPU to a LAN or to a network card in a PC.

2.Launch a browser on your PC.

3.Type http://192.168.0.251 (the default APWeb IP address) in the address bar of the browser and press Enter.

The Enter Network Password dialog box opens.

Note: If the Enter Network Password dialog box does not open, see page 93 for troubleshooting strategies.

4.Enter the (case sensitive) default admin user name: super

5.Enter the (case sensitive) default admin password: super

6.Click OK.

APWeb opens to the Home page for the Network Administrator.

(The user’s Home page has limited access and can be opened by entering the default user name and password of none and none, i.e., the character string n-o-n-e.)

68

Octaire Instruction Manual

Page 73
Image 73
AMX Octaire Opening the APWeb Server, System Requirements, Design Requirement, To set up the APWeb server