Appendix B – Programmer’s Interface for System Diagnostics
Splash Screen Examples
Following are three examples of splash screen information that could display when different verbosity/ component settings are specified. Depending on the amount of detail provided, you may need to scroll to see the entire display.
~scri7v1!
[7:System Sensors] detected [center board sensors] detected
FIG. 46 Display for i7v1 (component 7, verbosity 1)
~scri7v3!
[7:System Sensors] detected [center board sensors] detected
[temp 1] 30.5c [temp 2] 32.0c
FIG. 47 Display for i7v3 (component 7, verbosity 3)
~scri3v3! |
|
|
[3:Communication | Interfaces] count = 3 | |
[interface 1] | detected |
|
[type] BCS | mode RS232 port, | 9600 (8/1/N/E/NS) |
[interface 2] | detected |
|
[type] BCS | mode RS232 port, | 115200 (8/1/N/NE/NS) |
[interface 3] | detected |
|
[type] MCF5282 FEC Ethernet | Controller |
FIG. 48 Display for i3v3 (component 3, verbosity 3) |
|
Octaire Instruction Manual | 99 |