Installation & Setup
Installation & Setup
Site Recommendations
When placing the enclosure, follow the recommendations and precautions in this section to reduce potential installation and operation hazards. For general specifications, see page 13; for individual signal specifications, see the “Signal Types & Specifications” chapter (page 39).
Environment
Choose a clean, dust free, (preferably)
Avoid areas with direct sunlight, heat sources, or high levels of EMI (Electromagnetic
Interference).
Chassis Accessibility
Make sure the front and rear panels of the enclosure are accessible, so that you can monitor the LED indicators. Leaving adequate clearance at the rear will also allow for easier cabling and service.
Power
The source’s electrical outlet should be installed near the router, easily accessible, and properly grounded. Power should come from a building branch circuit. We recommend that a second, independent branch be used for the second AC inlet feed to the enclosure (see page 27). Use a minimum breaker current rating of 30 A for 110 V or 15 A for 230 V.
To avoid an overload, note the power consumption rating of all the equipment connected to the circuit breaker before applying power.
General Hazard Precautions
These recommendations address potential hazards that are common to all installations:
Elevated Operating Temperature
The maximum rated ambient temperature for Octaire enclosures is 113° F (45° C).
All equipment should be installed in an environment compatible with the manufacturer’s maximum rated ambient temperature. In a closed or
Caution: To protect the equipment from overheating, do not operate in an area that exceeds 113° (45° C) and follow the clearance recommendation below for adequate airflow.
Airflow Restriction
Octaire enclosures are designed to adequately dissipate the heat they produce under normal operating conditions; however, this design is defeated when high
Caution: To prevent overheating, avoid placing high