FRYER TROUBLESHOOTING GUIDE (Continued)
PROBLEM | CAUSE | REMEDY |
|
|
|
Liquid shortening does | 3. Loose knob on thermostat; or thermostat | 3. (Continued) |
not reach the desired | requires calibration (temperature setting | the shortening temperature has |
temperature for frying. | differs by about 10°F from measured | stabilized. |
(Continued) | shortening temperature). (Continued) | Measure the temperature of |
|
| the shortening by inserting an |
|
| accurate thermometer about |
|
| 4 inches into the shortening to |
|
| measure its temperature. If the |
|
| temperature difference between |
|
| the measured temperature and |
|
| the thermostat setting is 10°F |
|
| or less, the thermostat can be |
|
| recalibrated. |
|
| Recalibrate the thermostat by: |
|
| (a) removing the cap on the |
|
| thermostat control knob; (b) |
|
| loosening the center brass hex |
|
| nut portion of the knob; (c) turn |
|
| the pointer portion of the knob to |
|
| the measured temperature value |
|
| of the thermostat setting. |
|
| Tighten the brass hex nut to lock |
|
| the adjustment. Replace the |
|
| cap on the knob. |
| 4. Thermostat setting is more than 20°F dif- | 4. Check the thermostat setting |
| ferent than measured shortening tempera- | against an accurate measure of |
| ture. | the shortening temperature. If |
|
| the temperature difference is |
|
| greater than 20°F, the thermo- |
|
| stat can possibly be recali- |
|
| brated. |
|
| Recalibrate the thermostat by: |
|
| (a) removing the cap on the |
|
| thermostat control knob; (b) |
|
| loosening the center brass hex |
|
| nut portion of the knob; (c) turn |
|
| the pointer portion of the knob |
|
| to the measured temperature. |
|
| Tighten the brass hex nut to lock |
|
| the adjustment. Replace the |
|
| cap on the knob. |
|
| If this calibration is unsuccess- |
|
| ful, the thermostat has failed and |
|
| must be replaced. |
|
|
|
22