Anetsberger Brothers 14GS 14GU Caster Leveling Instruc, INSTALLATION INSTRUCTIONS Continued

Models: 14G 14GS 14GU

1 24
Download 24 pages 5.35 Kb
Page 9
Image 9
CASTER LEVELING INSTRUC-

INSTALLATION INSTRUCTIONS (Continued)

CASTER LEVELING INSTRUC-

CASTER LEVELING INSTRUC-

TIONS (Continued)

TIONS (Continued)

5.Completely unscrew the bolts holding the caster mounting plate that requires leveling adjustment. Retain the locking nuts for later reassembly.

6.Reinsert each bolt through its flatwasher and the fryer mounting bracket; next, place a spacer of the required thickness on the bolt before inserting the bolt through its mounting hole on the caster mounting plate and screw- ing a locking nut onto the bolt.

7.Repeat step 6 for all remaining bolts.

8.Tighten all four locking nuts evenly and securely against the caster mounting plate and the fryer bottom mounting bracket.

9.Return the fryer to its desired location and check again for wobbling or rocking. Repeat steps 3 through 8 until no wobbl- ing or rocking occurs. When the fryer no longer wobbles or rocks, perform step 10.

10.Next, perform the “Fryer Restraining Device Installation Instructions.”

FRYER RESTRAINING DEVICE INSTALLATION INSTRUCTIONS

! WARNING

Fryers MUST have a movement- limiting (restraining cable) device installed to prevent tipping that causes splashing or spilling of its HOT contents.

NOTE: This movement-limiting device is to be furnished and installed by the fryer’s install- ing contractor before the fryer is connected to the gas line at its desired location.

1.Install one restraining device connector into the structure wall directly behind the fryer’s desired location, as shown in Figure 2.

2.Install one restraining device connector on the rear panel of the fryer very close to the quick- disconnect device on the end of the fryer’s gas line.

3.Attach one end of the restraining cable to the wall connector. Attach the other end to the fryer connector.

4.Confirm that the fryer cannot move far enough away from the wall to cause excessive move- ment of the flexible gas line or its associated connectors.

9

Page 9
Image 9
Anetsberger Brothers 14GS 14GU warranty Caster Leveling Instruc, INSTALLATION INSTRUCTIONS Continued