21
4929B–AUTO–01/07
ATA6264 [Preliminary]
Necessary for operation:
VEVZ = 5.5V to 40V or VK30 = 5.5V to 40V, VK15 > 3V, VVINT = 3.7V to 5.47V
Operating conditions of all other supply pins:
VVSAT, VVPERI and VVCORE are within functional range limits, Tj = –40°C to 150°C
Other pins:
As defined in Section 4. ”Functional Range” on page 8.
Table 7-1. Electrical Characteristics – Charge Pump
No. Parameters Test Conditions Pin Symbol Min Typ. Max. Unit Type*
6.11 Supply current at pin CP CP off, supply of
internal circuitry CP ICP 050µAA
6.12
Time between wrong CP-OUT
voltage and valid data in status
register
CP-OUT td050µsA
6.13 Current limitation at pin
CP-OUT CP-OUT ICP-OUT –0.8 –4.2 mA A
6.14 Voltage difference VCP – VEVZ
for detecting wrong CP
Note: Threshold is in
the range of 5V to 7V CP VDiff 5VA
6.15
Time between wrong CP
voltage and valid data in status
register
CP td050µsA
6.16
Voltage difference VCP-OUT
VEVZ for detecting wrong
CP-OUT
Note: Threshold is in
the range of 5V to 7V CP-OUT VDiff 5VA
6.17 Voltage at pin CP
VEVZ = 5.5V to 40V,
VK30 < VEVZ
ICP+I
CP_Out= –100 µA
(current consumption of
VSAT and VCORE have to
be added)
CP VCP VEVZ + 7 VEVZ + 11 V A
6.18 Voltage at pin CP
VEVZ = 5.5V to 40V,
VK30 < VEVZ
ICP+I
CP_Out= –100 µA
(current consumption of
VSAT and VCORE have to
be added)
CP VCP VK30 + 7 VK30 + 11 V A
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter