61
4929B–AUTO–01/07
ATA6264 [Preliminary]
17.11 Output voltage clamping
(VISENSVVPERI)
I
IASGx
>CR
Y
×
V
VPERI
/R
ISEN
S
(x = 1 to 5), (Y = 1, 2)
(VISENSVVPERI regulator
active)
ISENSE VISENSE 0.96 ×
VVPERI
1.05 ×
VVPERI VA
17.12 ISENS leakage current VISENS = 0V to 0.96 ×VVPERI ISENSE IISENSE –1.6 +1.6 µA A
17.13 IASGx leakage current
(x = 1 to 5)
IASGx channel deactivated,
0V < VIASGx < VEVZ
IASGxIIASGx –1.6 +1.6 µA A
Table 18-1. Electrical Characteristics (Continued)–Voltage/Current Sources (IASGx Sources)
No. Parameters Test Conditions Pin Symbol Min Typ. Max. Unit Type*
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter