72
4929B–AUTO–01/07
ATA6264 [Preliminary]
The initial programming command is only available in Test mode. For more information aboutthe programming flow and the register contents, see Section 5.2 ”Initial Programming of theATA6264” on page 11.Table 22-6. Initial Programming (IP Command)
Description
MSByte LSByte
Hex Code7654321076543210
Write data to IP register 1 0 1 0 1 0 0 1 x x x x x x x x A9xx
Table 22-7. Diagnosis Commands
Description
MSByte LSByte
Hex Code7654321076543210
Set UZP to tristate mode
and switch off all
measurements
1100000000000000 C000
Switch VEVZ via AMUX to
UZP 1100101000110001 CA31
Switch VVSAT via AMUX to
UZP 1100101000110010 CA32
Switch 90% × VVPERI via
AMUX to UZP 1100101000110100 CA34
Switch 10% × VVPERI via
AMUX to UZP 1100101000111000 CA38
Switch VVCORE via AMUX to
UZP 1100101001100001 CA61
Switch VK15 via AMUX to
UZP 1100101001100010 CA62
Switch VK30 via AMUX to
UZP 1100101001100100 CA64
Switch VIREF via AMUX to
UZP 1100101001101000 CA68
Switch VIASG1 via AMUX to
UZP 1100101010010010 CA92
Switch VIASG2 via AMUX to
UZP 1100101010010100 CA94
Switch VIASG3 via AMUX to
UZP 1100101010011000 CA98
Switch VIASG4 via AMUX to
UZP 1100101011000001 CAC1
Switch VIASG5 via AMUX to
UZP 1100101011000010 CAC2
Switch VUSP via AMUX to
UZP 1100101011000100 CAC4
Switch VK1 via AMUX to
UZP 1100101011001000 CAC8
Switch VK2 via AMUX to
UZP 1100101011100001 CAE1
Note: 1. UZP voltage will be influenced by the USP voltage