xiv
Appendix
IPDHCP
Selecting DHCP allows the FastStream to request an IP
address from the network. The network must have at least
one DHCP server.
Default: enabled
set IPDHCP [mp1] [enabled | disabled]
Requires a SaveConfiguration command
get IPDHCP [mp1]
IPGateway
Controls the current default gateways used by any
Ethernet port(s) on the unit. If IPDHCP is enabled, the
‘get’ command reports the current IP gateway assigned
by the network DHCP server.
Default: 0.0.0.0
set IPGateway [mp1] [xxx.xxx.xxx.xxx]
get IPGateway [mp1]
IPSubnetMask
Sets/displays the current subnet mask. If IPDHCP is
enabled (see above), get command reports current subnet
mask assigned by DHCP server. Setting this value always
modifies the internal NVRAM value of the IP subnet mask
whether or not a SaveConfiguration is performed.
Default: 255.255.0.0
set IPSubnetMask xxx.xxx.xxx.xxx
get IPSubnetMask
IsReserved
Displays the reservation status of the current unit.
IsReserved
MaxOpTemp
Regulates the maximum operating temperature of this
unit in degrees Celsius. Valid entries are between 55 and
70 degrees.
Default: 70
set MaxOpTemp [55 – 70]
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a
product via the command’s Start, Stop and Display
parameters.
Metrics [Start | Stop | Display] [drive [BlockDevID] | all |
running]
MinOpTemp
Regulates the minimum operating temperature of this unit
in degrees Celsius. Valid entries are between 0 and 15
degrees.
Default: 0
set MinOpTemp [0 – 15]
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid
entries are between 0 and 15 degrees.
Default: 0
set OpTempWarn [0 – 15]
get OpTempWarn
PartitionDisplay
Lists all the partitions available in the specified RAID
Group. The partitions are listed in order of
contiguousness (as opposed to index order).
PartitionDisplay [GroupName]
Password
Specifies password for all non-serial sessions: Telnet, ftp
and FastStream browser-based user interface. You are
prompted for the current password, to type the new
password, and to confirm the new password. If local
echo
is enabled, password echoes all * characters. In
verbose mode only, CLI requests the password be re-
typed. When the password is all
0
s, Telnet and ftp do not
validate the password and MD5 authentication is
disabled. Passwords are case sensitive and can be 1-32
characters long with no spaces.
Default: Password
set Password
Requires a SaveConfiguration command
Performance
Returns the performance data for the FC port you specify.
Data includes the average rate (MB per sec.) and number
of I/Os measured over the previous sampling period
where a sampling period is approximately one second.
Successful SCSI Read (08h, 28h) and Write (Oah, 2Ah)
commands are considered I/Os.Reported performance
may be affected by FC port and SCSI bus availability and
saturation, SCSI device speeds and overall system use.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
QuickTape
Sets up virtual tape configuration.
QuickTape [TapeLibraryName] [# tape drives] # tape
volumes] [RAID Group Name] [MC Vendor ID] MC
Product ID] [MC Revision] [TD Vendor ID] [TD
Product ID] [TD Revision] [Medium Type] [Hot
Spares RAID Group Name | disabled] <Barcode
prefix>