EmailNotifyAddress

Configures notification addresses using an index (a number between 1 and 5, inclusive), the full E-mail address of the recipient, a fully qualified Internet E-mail address not more than 128 characters long, and a level.

Levels are

None: no E-mails sent.

Critical: critical event notification.

Warning: warnings and critical event notification.

All: all warnings, critical events

set EmailNotifyAddress [index] [full email address] [warning level]

get EMailNotifyAddress

EmailPassword

Configures the password used to authenticate the login to the SMTP email server. The password must not be more than 64 characters. A password is not required if the email server does not require authentication.

set EmailPassword

EmailServerAddress

Configures the address of the server that the FastStream should contact in order to send E-mails.

Default: 0.0.0.0

set EmailServerAddress [IP address] get EmailServerAddress

EmailUsername

Configures the username used to authenticate the login to the SMTP email server. The username must not be more than 128 characters. A username is not required if the email server does not require authentication.

set EmailUsername [Username] get EmailUsername

EthernetMDIX

Specifies the Ethernet twisted-pair connection type.

The MDI setting connects the unit's Ethernet port to an Ethernet hub or switch port with a standard Ethernet patch cable (or to a PCI card with a cross-over cable).

The MDIX setting connects the unit's Ethernet port to an Ethernet PCI card with a standard Ethernet patch cable (or to a hub or switch with a cross-over cable).

The Auto setting attempts to automatically determine the correct setting.

Default: MDI

set EthernetMDIX [mp1] [MDI MDIX auto] get EthernetMDIX [mp1]

EthernetSpeed

Sets/displays the current speed of the Ethernet connection. Choices are 10, 100, and Auto.

Default: auto

set EthernetSpeed [mp1] [ 10 100 Auto ] Requires a SaveConfiguration command get EthernetSpeed [mp1]

EventLog

When enabled, records various system errors to the event log.

Default: enabled

set EventLog [enabled disabled] get EventLog

EventLogFilter

Filters data from specific unit subsystems and levels when event logging is enabled. The specific entries supported are platform-dependent.

Subsystem

Levels

ECC

INFO

ENET

WARN

GEN

CRIT

HTTP

FAIL

NVRAM

ALL

PERF

 

SCSI

 

NDMP

 

FC

 

ALL

 

set EventLogFilter [subsys all] [event level all] [all none]

get EventLogFilter [subsystem] [level]

Exit

Exits the current Ethernet telnet CLI session; it has no effect if used during a serial or in-band CLI session.

Exit

FCConnMode

Controls/reports the connection mode the FastStream uses when communication across a FC network, either to an arbitrated loop (FC-AL) when you select loop mode, or point-to-point when you choose ptp. If you choose loop-ptpor ptp-loop, the FastStream tries to use the first parameter first.

Default: loop

set FCConnMode [fp] [loop ptp loop-ptp ptp-loop] Requires a SaveConfiguration command

get FCConnMode [fp]

xii Appendix

Page 41
Image 41
ATTO Technology FastStream VT EmailNotifyAddress, EmailPassword, EmailServerAddress, EmailUsername, EthernetMDIX, EventLog