Scenarios for the Restart Process
Issue 2.2 April 2005 77
4. When control is passed to the software that was just loaded, the following messages
display:
This message continues while the new boot code is being written into RAM.
5. The telephone detects and displays the speed of the Ethernet interface in Mbps, that is, 0,
10, or 100. The message No Ethernet displays until the software determines whether the
interface is 10 Mbps or 100 Mbps.
Note:
Note: The Ethernet speed indicated is the LAN interface speed for both the telephone
and any attached PC.
6. The software determines whether sufficient IP address information was downloaded. I n this
scenario, it is discovered that sufficient information has not been downloaded. The
following message displays while the DHCP process is invoked:
The number of elapsed seconds is incremented once per second, until DHCP successfully
completes.
7. The following message displays while the TFTP or HTTP process is invoked:
The number increments once per second, until the TFTP or HTTP server responds.
8. The following message displays while the upgrade script downloads from the TFTP or
HTTP server:
where n is the number of KBs that have been downloaded.
Starting...
Updating boot code...
DO NOT UNPLUG THE
PHONE!
DHCP: 0 secs
* to program
TFTP: n
www.xxx.yyy.zzz HTTP: n uri
46XXUPGRADE.SCR
n KB received