3Installing a New G700 with an S8300
Install New Software on the S8300
128 Installation and Upgrades for G700 and S8300
December 2003
IP address of server 1 (required) — Enter the IP address of the primary S8700 server.
IP address of server 2 (optional) — Enter the IP address of the duplicated primary S8700 server.
If server 2 is present, this specific IP address must also be entered.
IP address of secondary server 1 (optional) — Enter the IP address of the secondary S8700
server.
IP address of secondary server 2 (optional) — Enter the IP address of the duplicated secondary
S8700 server
NOTE:
The CLAN boards must be TN799DP running version 5 or greater firmware. Be sure to
check the firmware version for these boards on the S8500 or S8700. For information on
how to upgrade the firmware on the S8500 or S8700, please see the section "Upgrade
Firmware in Selected Port Cabinet Packs" in Upgrading the Avaya Media Server
Configuration in the S8700 documentation portion of this documentation CD (‘‘Avaya
S8300, S8500, and S8700 Media Server Library CD, 555-233-825’’).
12 If you clicked the LSP option with an S8300, simply enter the IP address of the S8300 server.
13 Click Continue.
The Ethernet Adjuncts screen appears.
Ethernet Adjuncts Screen
14 In the Number of UPS Units field, select the number of Uninterruptible Power Supplies (UPS)
units connected to the S8300 Media Server. This number is usually 0 or 1.
15 If you enter 1 in the Number of UPS Units field, enter its IP address in the UPS 1 IP address field.
The system will use this address to trap power loss signals from the UPS.
16 (Optional) If you enter 1 in the Number of UPS Units field, enter the SNMP community strings
for the UPS in the SNMP Get and Set fields.
17 Click Continue.
The External DNS Server Configuration screen appears.