8Connecting Telephones and Adjunct Systems
Installation and Wiring Telephones and Power Supplies
330 Installation and Upgrades for G700 and S8300
December 2003
4Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate
pins on the MM711 Media Module. Table 12, Two-Wire Station Pinout Chart, on page 330 shows
a pinout chart for two-wire stations.
5Administer using Administrator’s Guide for Avaya Communication Manager.
Figure 23: 2500-Type Analog Telephone Wiring
Table 12: Two-Wire Station Pinout Chart
Jack Name 1 2 3 4 5 6 7 8
BRI-T +TX +RX -RX -TX -V GND
ADJUNCT +Vadj T0 -V GNDVoice RRVoic
e+V S0 TTVoice
DSS
(QUEST) DTX DRX OKdi
g-V +V
DSS (ISDN)
BRI-A GND TX RX -V
BRI-U TX RX -V GND
DCP TX1 TX2 RX1 RX2 -V +V
ANALOG TIP RING
HANDSET -TX +RX -RX +TX
Figure notes
12500-Type Analog Station 2MM711 Analog Media Module,
Position 1V301
2500wireRBP 071996
3
28
03
2T
R
T.3
R.3