5
Upgrading an Existing G700 with an S8300 — R1.x to R2.0
Upgrade the S8300
Installation and Upgrades for G700 and S8300 249
December 2003
Verify Operation
Using the Maintenance Web Interface:
1Under Server click Process Status.
2Select "Summary and Display once" and click View to access the View Process Status Results
page.
3Make sure everything except ENV, arbiter, and dupmgr shows UP. Communication Manger should
show 65/65 UP or, if IA770 is installed, 67/67 UP.
The number of processes (67/67) may vary depending on the configuration. For a normal state,
the second number should not be greater than the first number. For example, the numbers 66/67
UP would indicate that a process did not come up and should be investigated before proceeding.
4Using a telephone, make test calls to verify that call processing is working.
Next Steps
This completes the S8300 upgrade process for upgrading from a 1.x software release to release 2.0. You
now must upgrade the G700 and media module firmware and then install and restart IA770, if installed