6Upgrading an Existing G700 with an S8300 — R2.0 to R2.x
Complete the Upgrade Process (S8300 is the Primary Controller)
298 Installation and Upgrades for G700 and S8300
December 2003
Complete the Upgrade Process (S8300 is the Primary Controller)
Telnet to the S8300 (primary controller) and open a SAT session to complete the following procedures.

Check Media Modules

1Type list configuration all and press Enter.
2Verify that the software is communicating with all media modules and that all media modules are
listed in the reports.
3Make test telephone calls to verify that Communication Manager is working.

Enable Scheduled Maintenance

1Type change system-parameters maintenance and press Enter.
2Ensure that the Start Time and Stop Time fields’ administration is the same as before the
upgrade.

Busy Out Trunks

1Busy out trunks that were busied out before the upgrade (see Record All Busyouts).

Check for Translation Corruption

1Type newterm and press Enter.
If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing the upgrade.

Resolve Alarms

1On the Maintenance Web Interface, under Alarms click Current Alarms to examine the alarm
log.
2If any alarms are listed, click Clear All.
3Resolve new alarms since the upgrade through Communication Manager using the appropriate
maintenance book.

Re-enable Alarm Origination

1Telnet to the S8300 and log on.
2At the command prompt, type almenable -d b -s y, where