AXIS 225FD - Unit Connectors

Unit Connectors

This section describes the following:The I/O terminal block

LED indicators

Power connection

I/O Terminal Block

The 7-pin I/O terminal connector provides the interface to a solid state relay output, two digital inputs, RS-485/422 and GND.

The terminal connector is used in applications for e.g. motion detection, event triggering, time lapse recording, alarm notification via email, image storage to FTP locations, etc.

Input - Used for connecting external alarm devices and triggering images for specific alarm-based events. The input is typically connected to a motion detector or any other external security device, and images can be uploaded whenever the detector is activated. Con- nect to GND to activate.

Power connector block

C

 

o

r

AC

 

D

 

 

 

 

 

 

 

A

+

 

G

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

7

 

 

 

 

 

 

I/O terminal

 

 

 

 

 

 

block

 

 

 

 

 

 

Control button

Network

connector

Output - This can drive a maximum load of 50VDC or 35VAC at 100mA directly or heavier loads by connect- ing additional relay circuitry. If the output is used with an external relay, a diode must be connected in parallel with the load for protection against any volt- age transients.

I/O terminal connector block pinout:

LED indicators

1 2 3 4

Conduit hole and plug

Pin

Function

Description

 

 

 

1

Output A

On the external device output terminals (A and B), there is no distinction between positive and nega-

 

 

tive (+ and -). The terminals use a photocoupler and are electrically isolated from the other internal

2

Output B

 

 

circuitry.

 

 

The maximum load should not exceed 100mA and the maximum voltage should be not more than

 

 

50VDC or 35VAC.

 

 

 

3

Digital Input 1

Connect to GND to activate, or leave floating (or unconnected) to deactivate.

 

 

 

4

Digital Input 2

 

 

 

 

5

RS-485/422-A

A half-duplex RS-485 interface for controlling auxiliary equipment.

 

(non-inverting)

 

 

 

 

6

RS-485/422-B

 

 

(inverting)

 

 

 

 

7

GND

Ground.

 

 

 