MSWU-81E 07/08/2013 63
13.Service
13.2 Service message of the projectorThe functions covered in this unit relate to the display of som e basic information about the projector.
Memory of the custom timing files will be er ased in the Factory Reset operation
• Model: the designated model number of the projector.
• Serial Number: the designated serial number of th e projector.
• Software Version: the version of software ins talled on the projector.
• Active/PIP Source: displays the current PIP sources.
• Pixel Clock: displays the pixel clock of the current i nput signal.
• Signal Format: displays the format of the current in put signal.
• H/V Refresh Rate: displays the horizontal and ver tical refresh rates for the current image.
• Lamp1 Run Time: displays Lamp1's current run time.
• Lamp2 Run Time: displays Lamp2's current run time.
• Projector Run Time: displays the projector 's total operating hours.
When a lamp's run time has reached 1200 hours or when you not ice the projected image to be noticeably
dimmer, please replace the lamp
13.3 Lamp Hour ResetUse this function to reset the hours for lamp1 and lamp2 to zero.
After replacing the lamp, remember to reset the lamp hou rs to ensure the accuracy of lamp hours
displayed in the OSD Menu.
13.4 Blue OnlyEnabling this option will make the projector dis play only blue color to facilitate the process of image in spection for the service
personnel. For detailed instructions on how to use this function, consult a qualified service personnel.
13.4 Factory ResetAll settings of the projector will be set to the or iginal factory settings. All us er settings are erased with this operation .
This function will not apply to items includ ing no signal, network, Projector control, st artup Logo, language,
High Altitute mode and lamp hours
When Factory Reset is executed, all source memori es created by the projector (i.e. timings files) will be
erased