6. Configurator, General projector settings
Image 6-11
Input locking, free runop tions
Manual lock can be switched On or Off just by checking the check box next to Manual lock.
Manual
lock on :
locking is done on the indicated vertical frequency which can be changed by the user.
Manual
lock off :
locking is done on an internal sync (60 Hz).
Tochange the lo cking frequency for manual lock on, click on the up down control next to Vert freq until
the desired value is reached or
click in the input eld, select the current value and enter a new value with the ke yboard.
Options for Automatic or specic input
When Automatic or specic input is selected, the Genlock input settin gs become available.
Image 6-12
Inputloc king, automatic or specicinput options
Genlock can be switched On or Off just by checking the check box next to Genlock.
Genlock
off
(default position) locking done on input source of main window, when automatic was
selected or on the selected input source when a specic input was selected. Projector
detects automatically the vertical frequency and clock frequency of the input signal . A
slightly difference with the source is possible.
Genlock
on
locking done on indicated vertical frequency and clock frequency. This vertical frequency
and clock frequency must be exactly the same as those of the source.
Only use genlock ON for very stable sources and preferable for broadcast sourc es.
For Genlock on,
Tochange the Clock freq uency,click on the up down contr ol next to Clock freq until the desired value is
reached or
click in the input eld, select the current value and enter a new value with the ke yboard.
Tochange the Vertical frequency, click on the up down contro l next to Vert freq until the desired value is
reached or
click in the input eld, select the current value and enter a new value with the ke yboard.
R5976924 PROJECTO R TOOLSET 16/04/2 009 79