6. Configurator, General projector settings
When:
None Output is locked on an internal sync (60 Hz)
Automatic Output is locked on the selected input for the main window.
Available input
selected
Output is lockedon that selected input.
3. Click Close.
Image 6-10
Input locking
WhenInput locking is set to Automatic or on a specic input and there is no sync signal
available, the locking will be switched to Free run without changing the user settings.
Once the sync is available, it applies again the user settings.
Options for Free run
When Free run is selected, the Manual input settings become available.
78 R5976924 PROJECTOR TOOLSET 16/04/2009