En
7
1. Set the DIP switches. If you have only one OmniViewPRO, use the MASTER
bank setting. If the OmniViewPRO you are using will be daisy-chained off
another unit, use a unique slave setting. Please refer to the previous section
for more information.
DIP SWITCH #
3456
ON ON ON ON BANK 0 MASTER
OFF ON ON ON BANK 1 slave
ON OFF ON ON BANK 2 slave
OFF OFF ON ON BANK 3 slave
ON ON OFF ON BANK 4 slave
OFF ON OFF ON BANK 5 slave
ON OFF OFF ON BANK 6 slave
OFF OFF OFF ON BANK 7 slave
ON ON ON OFF BANK 8 slave
OFF ON ON OFF BANK 9 slave
ON OFF ON OFF BANK A slave
OFF OFF ON OFF BANK B slave
ON ON OFF OFF BANK C slave
OFF ON OFF OFF BANK D slave
ON OFF OFF OFF BANK E slave
OFF OFF OFF OFF BANK F slave
NOTE: “ON” is down
2. Find a convenient place to put your OmniViewPRO. Its 19" form factor makes it
ideal for 19" racks. When mounting to a rack, attach the included brackets to the
sides of the OmniViewPRO. Take note of the length of your cables so that your
computers, OmniViewPRO, keyboard, mouse, and monitor are distanced properly.
PLEASE FOLLOW THIS INSTALLATION PROCEDURE EXACTLY. NOT DOING SO MAY
RESULT IN KEYBOARD AND/OR MOUSE ERRORS, OR FAULTY OPERATION.
WARNING: Before attempting to connect anything to the OmniView

PRO or the computers, make sure everything is powered off. Plugging and

unplugging cables may cause irreversible damage to your computers and

the OmniViewPRO. Belkin Components will not be held responsible for

damage caused.

Hardware Installation
BANK ADDRESS
F1D116_OSD_AM_man.qxd 4/20/00 4:07 PM Page 7