English

Indicators

Light

 

 

 

Status & Description

POWER

TEMP

LAMP1

LAMP2

 

 

Power events

 

 

 

 

Orange

Off

Off

Off

Stand-by mode.

Green

Off

Off

Off

Powering up.

Flashing

 

 

 

 

 

Green

Off

Off

Off

Normal operation.

 

 

 

 

1.

The projector needs 90 seconds to cool down as it was

Orange

 

 

 

 

abnormally shut down without the normal cooling

Off

Off

Off

 

down process. Or

Flashing

 

 

 

 

2.

The projector needs to cool for 90 seconds after the

 

 

 

 

 

 

 

 

 

power is turned off.

 

 

 

 

 

 

Orange

Off

Off

Off

The projector has shutdown automatically. If you try to re-

Flashing

 

 

 

start the projector, it will shutdown again. Please contact

Orange

Off

Red

Off

your dealer for assistance.

Flashing

 

 

 

 

 

Lamp events

 

 

 

 

Off

Off

Red

Off

Lamp 1 failed. The projector has entered Single-Alternative

mode automatically. Replace lamp 1 as soon as possible.

 

 

 

 

Off

Off

Off

Red

Lamp 2 failed. The projector has entered Single-Alternative

mode automatically. Replace lamp 2 as soon as possible.

 

 

 

 

 

 

 

 

 

 

 

 

 

The projector has shutdown automatically. If you try to re-

Off

Off

Red

Red

start the projector, it will shutdown again. Please contact

 

 

 

 

your dealer for assistance.

 

 

 

 

 

 

Thermal events

 

 

 

 

Off

Red

Off

Off

Off

Red

Red

Off

Off

Red

Green

Off

Off

Red

Orange

Off

Off

Red

Off

Red

Off

Red

Off

Green

Off

Red

Off

Orange

Red

Red

Red

Off

Red

Red

Green

Off

Red

Red

Orange

Off

Green

Red

Red

Off

The projector has shutdown automatically. If you try to re- start the projector, it will shutdown again. Please contact your dealer for assistance.