BenQ W20000, W5000 Displaying more than one image source simultaneously, PIP source conflict list

Models: W20000 W5000

1 53
Download 53 pages 17.21 Kb
Page 32
Image 32

W20000-en.book Page 32 Monday, October 22, 2007 3:35 PM

English

Displaying more than one image source simultaneously

Your projector is capable of displaying pictures simultaneously from two input sources, which can be used to enhance your presentation in an interesting way. Ensure the signals you want to display are correctly connected to the projector.

To display the PIP window:

Using the remote control

Press PIP to display the PIP page and make adjustments by following the steps starting from step 3 in the section "Using the OSD menu" below.

When the PIP window is on, to change the PIP window size, press SIZE repeatedly until a desired size is selected.

When the PIP window is on, to change the PIP window position, press POSITION repeatedly until a desired position is selected.

When the PIP window is on, to highlight one of the sources to make adjustments, press ACTIVE repeatedly until the source is selected.

Using the OSD menu

1.Press MENU and then press / until the Display menu is highlighted.

2.Press to highlight PIP and press ENTER. The PIP page displays.

3.Highlight PIP and press / to select On.

The projector will select two currently active signals to display and the last viewed picture will be displayed on the big screen as a main source.

See "PIP source conflict list" on page 32 for the conflict source combinations.

4.To change the Main Source or Second Source, press to highlight Main Source or Second Source and press ENTER. The source selection bar displays.

5.Use / to highlight the source you want to display for the main (bigger) or second (smaller) window, and press ENTER to save the setting and go back to the PIP page.

6.To make OSD settings to one of the two sources (main or second),

highlight Active Window and press / to select the source you want to make adjustments.

The settings made on the OSD menus will only take effect on

the active window. See "Disabled functions for the active windows" on page 32 for exceptions.

7.To change the position of the smaller picture, highlight Position and press / repeatedly until a suitable position is selected.

8.To resize the small picture, highlight Size and press / to set the PIP size among Small or Large.

Display

Aspect Ratio

Anamorphic

Keystone

 

 

 

Position

 

 

 

Overscan Adjustment

0

 

 

 

 

 

 

PIP

ENTER

 

PC & Component YPbPr Tuning

 

 

S-Video

EXIT Back

PIP

 

 

 

PIP

On

 

Main Source

 

 

 

Second Source

 

 

 

Active Window

Main

Position

Top-Right

Size

Large

EXIT Back

9.To save the settings and leave the OSD menu, press MENU once or EXIT repeatedly until the menu disappears.

PIP source conflict list

The following source combinations cannot display at the same time for the PIP function: Component+Video, Component+S-Videoand Video+S-Video.

Disabled functions for the active windows

The following OSD menu functions cannot work on the active windows for the PIP: My Screen, Auto Source Search.

32 Using the projector

Page 32
Image 32
BenQ W20000, W5000 user manual Displaying more than one image source simultaneously, PIP source conflict list