English
Timing of replacing the lamp
When the Lamp indicator lights up red or a message appears suggesting it is time to replace the lamp, please install a new lamp or consult your dealer. An old lamp may cause a malfunction in the projector and in some instances the lamp may explode.
The Lamp indicator light and Temperature warning light will light up if the lamp becomes too hot. Turn the power off and let the projector cool for 45 minutes. If the Lamp or Temp indicator still lights up after turning the power back on, please contact your dealer. See "Indicators" on page 47 for details.
The following Lamp warning displays will remind you to change the lamp.
Status | Message | |
The lamp has been in operation for 2000 hours. Install a new lamp for | WARNING | |
optimal performance. If the projector is normally run with Whisper selected | ||
NOTICE: Order replacement lamp | ||
(See "Getting to know the lamp hour" on page 43), you may continue to | ||
| ||
operate the projector until the 2950 hour lamp warning appears. | Lamp > 2000hrs | |
| ||
Press ENTER to dismiss the message. |
| |
| OK | |
|
| |
The lamp has been in operation for 2980 hours. It is strongly recommended | WARNING | |
that you replace the lamp at this age. The lamp is a consumable item. The | ||
NOTICE: Order replacement lamp | ||
lamp brightness diminishes with use. This is normal lamp behavior. You can | ||
| ||
replace the lamp whenever you notice that the brightness level has | Lamp > 2980hrs | |
significantly diminished. If the lamp is not replaced beforehand, it should be |
| |
replaced after 2950 hours usage. |
| |
Press ENTER to dismiss the message. | OK | |
|
| |
The lamp has been in operation for 3000 hours. The lamp MUST be replaced | WARNING | |
before the projector will operate normally. | ||
NOTICE: Replace lamp now | ||
| ||
Press ENTER to dismiss the message. | Lamp > 3000hrs | |
| ||
| ||
| Replace lamp (refer to User Manual) | |
| then reset lamp timer | |
| OK | |
|
|
Replacing the lamp
To reduce the risk of electrical shock, always turn the projector off and disconnect the power cord before changing the lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replacing the lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution when removing lamp glass that has shattered into sharp pieces.
To reduce the risk of injuries to fingers and/or compromising image quality by touching the lens, do not touch the empty lamp compartment when the lamp is removed.
This lamp contains mercury. Consult your local hazardous waste regulations to dispose of this lamp in a proper manner.
44 Additional information