8 - INSTALLATION

Black Box®LB1350A/LB1351A

8 - INSTALLATION

For Half-Rack Mount installation:

Use the optional bracket kit, affix it to the unit. Then use 4 standard bolts and nuts (not supplied), and fasten well to the rack.

Make sure to leave a gap of at least 2-3cm above the unit.

For wall mount installation

Three suitable holes on the back of the Black Box® LB1350A/LB1351A permit wall mount Installation either horizontally (preferred) or vertically.

Two holes are 188mm apart for horizontal wall mount installation, for vertical wall mount installation the two holes are 107mm apart.

Use two suitable screws having heads diameter less than 8mm

For Desktop use: Affix the supplied plastic “feet” (after peeling off the adhesive protecting sheet) to the bottom of the devices, with each “foot” approximately 1 cm from each edge.

Place the device horizontally on a hard, clean surface (desk, shelf, etc.), leaving free space around it for natural ventilation. Avoid putting the device on other active, heat generating equipment and avoid putting such devices on the Black Box®LB1350A/LB1351A

19” Rack installation

Use a standard flat shelf, install it in the rack and place one or two Black Box®LB1350A/LB1351A side by side on the shelf. Make sure to leave a gap of at least 2-3cm above the unit.

9 - POWER CONNECTION

CAUTION: When connecting a device to an AC) power outlet, always first connect the cord to the device, and ensure that it is securely fastened. Only afterward connect the cord to the wall outlet .Make sure to use grounded ( 3 way ) outlets.

For each country Black Box provides with the product an appropriate power supply cord which is safety approved in accordance with such country’s National Electric Code

Black Box®LB1350A/LB1351A

Connect AC line voltage at the rear of the converter, using the included power cord. The Black Box®LB1350A/LB1351A will accept any line voltage from 100 to 240 VAC, 50-60 Hz.

There is no ON/OFF switch on the device. When the power is connected to the device, the device is ON. This will be indicated by the POWER LED ON.

Important: following any connection or setup change (sections10,11,12 below) you must reset the device by either using S9 or by disconnecting power and reconnecting it after few seconds