Black Box®LB1350A/LB1351A

Network parameters

IP address: specify here the IP address you wish to assign the management module. This parameter must be set correctly (according to your network) in order to remotely control and monitor your device from a management station.

Subnet mask: specify the required subnet mask to use within the network.

Default gateway: specify the default gateway to be used by the management module where applicable.

Console parameters

Baud rate: set the baud rate of communication between the Black Box® LB1351A and the terminal. It is recommended to leave this setting at default (9600baud).

SNMP parameters

Get community: specify the get community string for the device.

Set community: specify the set community string for the device.

Trap destination: specify the IP address of the remote manager that will receive the traps sent by the Black Box® LB1351A.

Trap community: specify the trap community string for the device.

System name: specify a name that identifies the device.

System location: specify the physical location of the device. Setting this parameter properly helps to monitor the network and maintain order within it.

Contact name: specify the person (most likely system or network administrator) that is responsible for managing and/or handling the converter.

Start up delay: specify how many seconds the management module should wait between the appearance of the start-up screen and the system initialization. During this time it is possible to change the management parameters configuration.

Updating parameter storage. This may take a while...Done

Initialization...

Figure 2-3 configuration complete; initialization

Your Black Box® LB1351A is now ready to be managed. The Ready LED should now be lit steady.

Disconnect the control cable and store it properly (unless you wish to manage the Black Box® LB1351A through a terminal).

21

Page 21
Image 21
Black Box LB1351A, LB1350A manual Network parameters, Console parameters, Snmp parameters