Black Box®LB1350A/LB1351A

Advanced port configuration

Advanced port configuration table is located under flLta31mPorts/flLta31mPortAdvanced in the device’s MIB sub-tree. The table is shown in figure 7-7.

figure 7-7 – advanced port configuration

SNMP traps

The management application also allows you to receive traps sent by the device (figure 7-8). Traps are sent by the Black Box® LB1351A after every configuration change. In addition traps will be sent to alert of the following events:

System up (cold start)

Temperature (when exceeds 650C for more than 1 minute)

TP link down

FO link down

TP link up (after at least 10 seconds down)

FO link up (after at least 10 seconds down)

Device reset (management initiated)

*traps for configuration changes will specify the initiator of the change (either local user or remote manager) where applicable.

35

Page 35
Image 35
Black Box LB1351A, LB1350A manual Advanced port configuration, Snmp traps