Black Box®LB1350A/LB1351A
Problem | Indication | Corrective Action |
|
|
|
|
| Check the interconnection between the |
|
| Black Box®LB1350A LB1351A and the |
|
| device. |
Black Box®LB1350A or | FDX LED not lit | Verify that connected device is FDX |
LB1351A not recognizing |
| capable and set to FDX properly. If HDX |
full duplex |
| then the indication is correct and you have |
|
| to setup the S7 Dip switch accordingly |
|
| Check the interconnection between the |
|
| Black Box®LB1350A/LB1351A and the |
|
| device. |
Fiber link not working | Link LED | Check that the receive fiber is properly |
| (100BaseFX) | connected to the transmit port of the |
| not lit | remote fiber device AND the transmit port |
|
| to the receive port of the remote device. |
| Remote device | Change to TEST mode (S8 UP) and verify |
| reports LINK | with remote operator to establish whether |
| DOWN | incoming or outgoing paths failed |
|
| Check that the fiber optic power is higher |
|
| than |
|
| connector at the Black Box®LB1350A |
|
| /LB1351A end. |
|
| Check that remote device’s receive port is |
|
| properly connected to the transmit fiber |
|
| optic port of the Black Box®LB1350A |
|
| /LB1351A |
|
| Verify FDX mode of the F/O port (S7 Down) |
|
| ; reset device by S9 |
No | F/O LED OFF | Disable FEF: Dip switch # 8 in Up position |
|
| (section 12 page 14) |
Improper network traffic | Runt and late | Reset the device using S9 |
| collision |
|
|
|
|
|
| Check configuration (section 12 ) on the |
|
| “mode setup switches”. |
|
| Check that both ends of F/O link are set to |
|
| same mode (Half Duplex OR Full Duplex). |
|
| Check that both sides of UTP connection |
|
| are in same mode (10Mbps Half duplex OR |
|
| 10Mbps full duplex OR 100Mbps Half |
|
| duplex OR 100Mbps full duplex). |
If the problem persists after carrying out the above procedure, do the following: replace the installed Black Box®LB1350A LB1351A,with another similar device and