Black Box®LB1350A/LB1351A
The broadcast protection indicates the relative amount of broadcast traffic that will be forwarded by the Black Box® LB1351A, starting at 25% maximum and down to 3% minimum. Default value is 25%.
The DSCP codes are represented as a series of 8 bytes, corresponding to 64 bits. These bits correspond, in turn, to 64 different DSCP codes. If you wish, for instance, to set code 45 as high priority, then bit 45 in this series needs to be set to ‘1’ (this is done though the control menus, described later). Default values are all 0s (meaning all codes are low priority).
The user priority codes are used in conjunction with the 802.1p based priority scheme. For example, if a tagged frame arrives with a priority code of 6, the Black Box® LB1351A will look priority code 6 to see if it is set as high or low priority and handle the frame accordingly. Default values are low priority for codes
The device control menu
The device control menu, shown in figure
Device control:
===============
1.TP port 1 control
2.TP port 2 control
3.TP port 3 control
4.FO port 4 control
5.Device reset
6.Basic device control
7.Advanced device control
8.Management control
0.return to main menu Select
figure 6-5 – device control menu
Options 1 through 4 will invoke the corresponding port’s control menu. Option 5 will result in a device reset (which will return the relevant configuration settings to the switches position). Options 6 and 7 will bring up the device control menu, respectively and the eighth option will get you to the management virtual port’s settings.
All control functions are located in the same tables of the device’s MIB
27