NOTE: Switches 1, 2, and 3 sets the number of messages in a single queue sequence. The timing between those messages is set by switches 4, 5, and 6. Switch 7 sets the total possible number of messages for the unit. Switch 8 is always in the ON position.

 

5

Set the MDMU options on the DIP switch. Refer to

 

 

the table below.

 

 

 

REM OPTION BATTERY

SWITCH OFF ON

Figure 6 Set MDMU Options on DIP Switch

Table 1. DIP Switch Setting Definitions

 

MAX. No. of

SET

SET

SET

SET

SET

SET

SET

 

 

MESSAGES IN

SWITCH

SWITCH

SWITCH

SWITCH

SWITCH

SWITCH

SWITCH

 

 

SEQUENCE:

# 1 TO

# 2 TO

# 3 TO

# 4 TO

# 5 TO

# 6 TO

# 7 TO

 

 

 

 

 

 

 

 

 

 

 

1

ON

ON

ON

 

 

 

 

 

 

 

 

 

 

 

2

OFF

ON

ON

 

 

 

 

 

 

 

 

 

 

 

3

ON

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

4

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

 

5

ON

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

6

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

7

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

8

OFF

OFF

OFF

 

 

DEFAULT DELAY BETWEEN MESSAGES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:05

ON

ON

ON

 

 

 

 

 

 

 

 

 

 

 

0:10

OFF

ON

ON

 

 

 

 

 

 

 

 

 

 

0:30

ON

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

1:00

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

5:00

ON

ON

OFF

 

15:00

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

30:00

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

NUMBER OF MESSAGES AVAILABLE:

1 TO 9

01 TO 99

ON OFF

5

Page 8
Image 8