5
Set the MDMU options on the DIP switch. Refer to
the table below.
NOTE: Switches 1, 2, and 3
sets the number of messages in
a single queue sequence. The
timing between those
messages is set by switches 4,
5, and 6. Switch 7 sets the
total possible number of
messages for the unit. Switch
8 is always in the ON position.
REMOPTION BATTERY
SWITCH OFF ON
Figure 6 Set MDMU Options on DIP Switch
Table 1. DIP Switch Setting Definitions
MAX. No. of
MESSAGES IN
SEQUENCE:
SET
SWITCH
# 1 TO
SET
SWITCH
# 2 TO
SET
SWITCH
# 3 TO
SET
SWITCH
# 4 TO
SET
SWITCH
# 5 TO
SET
SWITCH
# 6 TO
SET
SWITCH
# 7 TO
1
ON ON ON
————
2
OFF
ON ON
— — ——
3
ON OFF ON
— — — —
4
OFF
OFF ON
————
5
ON ON
OFF
— — — —
6
OFF
ON
OFF
————
7
ON OFF
OFF
— — — —
8
OFF
OFF
OFF
————
DEFAULT DELAY BETWEEN MESSAGES:
0:05
—— —
ON ON ON
—
0:10
———
OFF ON ON
—
0:30
———
ON
OFF
ON
—
1:00
———
OFF
OFF
ON
—
5:00
—— —
ON ON
OFF
—
15:00
— — —
OFF ON
OFF
—
30:00
———
OFF
OFF
OFF
—
NUMBER OF MESSAGES AVAILABLE:
1 TO 9
ON
01 TO 99
——————
OFF
5