Bosch Appliances D7212G Telephone Connections 6.0Telephone Connections, 6.1Registration, Location

Models: D7212G

1 68
Download 68 pages 20.47 Kb
Page 31
Image 31
Telephone Connections

D7212G

Telephone Connections

6.0Telephone Connections

6.1Registration

The Bosch Security Systems D7212G Control/Communicator is registered with the Federal Communication Commission under Part 68, for connection to the public telephone system using an RJ31X or RJ38X jack installed by the local phone company.

Note:

An RJ31X jack can be modified by placing a jumper wire between Terminals 2 and 7 to become an RJ38X jack.

6.2Notification

Do not connect registered equipment to party lines or coin-operated telephones. The local telephone company must be notified and supplied with the following information before connecting the panel to the telephone network:

The particular line to which the panel will be connected

Make (Bosch Security Systems), model (D7212G), and serial number of the panel

FCC registration number and ringer equivalence for the panel:

- FCC Registration Number: AJ9MUL-46532-AL-E

 

 

 

 

RJ31X

RJ31X

 

RING (red)

 

 

 

Jack

 

 

TIP (green)

- Ringer Equivalence: 0.1B

 

R1

R

T T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.3

Location

 

1

2

4

5

7 8

 

 

 

 

 

 

To prevent jamming of signals, wire the RJ31X or RJ38X jack

 

 

 

 

 

 

before the in-house phone system to support line seizure. See

 

1

 

4

5

8

 

 

 

 

 

TELCO

Figure 8. Install the jack on the street side of the phone switch,

(TIP)

(RING)

 

 

 

Connector

 

 

 

Block

 

 

 

 

 

wired ahead of any PBX equipment. Line seizure provides for a

 

1

 

4

5

8

 

 

 

 

temporary interruption of normal phone usage while the

 

 

 

 

 

 

communicator transmits data. After installation, confirm that

 

 

 

 

 

 

the panel seizes the line, acquires dial tone, reports correctly to

 

Outside

 

 

 

 

the receiver, and releases the phone line to the in-house phone

 

TELCO

 

 

 

 

 

 

 

 

 

 

system.

 

 

 

 

Premises

 

 

 

 

 

Telephone

 

6.4

Phone Cord Connection

 

Figure 8: RJ31X Wiring

Connect one end of a D161 (7 ft. [2.1 m]) or D162 (2 ft. [61 cm]) Telephone Cord to the TELCO Cord connector located on the bottom left corner of the panel. See Figure 9. Connect the other end to the RJ31X or RJ38X jack.

Note:

To supervise the phone cord, use an RJ38X jack.

 

 

 

 

 

 

 

 

 

 

 

 

Telephone Cord

 

 

 

 

 

 

 

 

 

 

 

 

 

E

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

N

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

GROUND START

RED PHONE

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

Requires

LED

11

12

13

14

15

16

17

18

19

20

21

22

L

 

 

Relay Model

ON WHEN

L

GRN

 

D136 in Ground

COMMUNICATING

 

 

 

 

 

 

 

 

 

 

 

 

E

E

 

 

Start Socket

OFF WHEN IDLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone LED

 

 

 

 

 

 

Operation Monitor

 

 

 

 

 

 

(Red)

 

 

 

 

 

 

 

 

LED (Green)

 

 

 

Figure 9: Phone Connector and LED and Operation Monitor LED Locations

6.5Phone LED (Red)

The red Phone LED lights when the panel seizes the phone line and remains lit until the panel returns the phone line. See Figure 9 for the location of the red LED.