Bosch Appliances GWH 2700 ES NG, GWH 2700 ES LP, ESVVT manual Specifications Technical data

Models: ESVVT GWH 2700 ES LP GWH 2700 ES NG

1 60
Download 60 pages 19.85 Kb
Page 5
Image 5

Appliance details

2.2Specifications (Technical data)

Approved in US/Canada

Capacity

Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F (25°C) rise.

Maximum output

160,500 Btu/h (47.0 kW)

Maximum input

199,000 Btu/h (58.3 kW)

Efficiency in %

Thermal efficiency > 82%

Min. Input

19,900 Btu/h (5.8 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C)

Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot water flow rate)*

Propane: 8” - 13” water column

Natural Gas: 3.5” - 10.5” water column.

*To measure gas pressure, see Measuring Gas Pressure, chapter 3.12.

Water

Hot water connection (inches) - ¾”

Cold water connection (inches) - ¾”

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.65 gallon/minute (2,5 l/m).

Note: Activation varies with inlet water temperatures from 0.65 - 1.6 gallon/minute.

Minimum recommended water pressure: 30 PSI (2.07 bar)

Minimum recommended well pressure: 40 PSI (2.75 bar), see chapter 3.9.

Connections:

– Bottom of heater

Combustion

NOx 40 Ng/J (Nanograms of NOx (calculated as NO2) per Joule of heat output).

CO 250 ppm (measured)

CO2 level set from factory, see chapter 6.4.

Dimensions

Depth (in): 11¼” (286 mm)

Width (in): 17 7/8” (452 mm)

Height (in): 30½” (775 mm)

Weight: 67 pounds (30,5 kg).

Gas types

Natural Gas. LP Gas.

Converting the gas type can only be done by a certified gas technician with a calibrated CO2 analyzer.

Call Bosch Water Heating through Bosch thermotechnology corp. for conversion instructions.

Voltage

120 V AC (60 Hz) nominal

Amperage

Idle - 40 mA

Operation - 2.5 A

Noise

45 - 65 db (A)

Safety devices

Flame failure device (ionization flame rod sensor)

Pressure relief valve (supplied with heater)

Over heat prevention (temperature limiter)

Inlet temperature sensor

Outlet temperature sensor

Backflow temperature sensor.

Water protection

IP X4 (protection against water drops)

If appliance is installed at elevations above

i2000ft, refer to section 3.3.6 Fan speed adjustment.

6 720 608 542

5

Page 5
Image 5
Bosch Appliances GWH 2700 ES NG, GWH 2700 ES LP, ESVVT manual Specifications Technical data